Low Voltage Electrical Product Testing
Latest News

ERA has now completed the RCD reliability study for The Electrical Safety Council. We tested 607 RCDs in properties owned by four Housing Associations and Local Housing Authorities.

The failure rate was 3.8% including six RCDs which had been deliberately shorted out, a dangerous practise. Excluding the shorted RCDs the failure rate was 2.8%, i.e. a pass rate of 97.2%. None of the occupiers ever tested the RCDs by pressing the test button.

See http://esc.org.uk/news-and-events/research/industry/rcd/january-08.html for further details.


Ensures electrical protection devices conform to appropriate standards with independent assessment and design support if required.

 

ERA Technology offers its customers a comprehensive and independent medium power testing service that provides them with confidence that their electrical protection devices conform to appropriate standards.

In addition, where problems in conformance are identified, expert advice is available to assist customers with any necessary design modifications.

With over 50 years' experience of helping customers design electrical protection devices correctly and safely.

ERA is able to develop and undertake bespoke testing to meet customers' requirements in addition to pre-defined testing against standards. ERA can also provide manufacturers with developmental testing and design validation helping speed products to market with ASTA, BSI or ERA certification.

ERA's test facilities include:
Single / Three phase 90V-1.1kV, 10A-6kA (1.1 MVA). Single phase 42.5kA @ 35V for <2s High and low speed data acquisition systems for recording voltages, currents and temperatures Testing at ‘point on wave’ capability.

Press play to see a fuse failing a test to BS 1362 1973. u
Download this video clip
Camera done by Lake Image Systems Ltd
e-mail: sales@lakeimage.com

Capability
Complete compliance and type tests for the following standards and IEC equivalent Standards:
fusesBS 88, BS 646, BS 6885, BS 1362, BS EN60127, BS EN 60269
switchgearBS EN 60439 and BS EN 60947
circuit breakersBS EN 60898
portable residual current devices (PRCDS) BS7071
miniature circuit breakers (MCBS) BS 3871
earth clampsBS 951
residual current circuit breakers (RCCBS) BS EN 61008 and BS EN 61009
power suppliesBS EN 61558
cut-outsBS 7657
surge protection devices (SPD)BS EN 61643-21, BS EN 61643-1, BS EN 61643-11
   
Quality Assurance
The need for confidence in the resulting data is paramount and ERA addresses this by holding a company-wide BS EN ISO 9001 certification. In addition the medium power facility specifically complies with NAMAS M10, ISO Guide 25, BSEN 45001 and BSI or ASTA accreditation with UKAS (registration 0512).
Detailed Accreditation Schedule

ERA's Quality Assurance System is also capable of being implemented in order to meet the specific contractual and technical requirements of each individual project.

Contact Information
Tel: +44 (0)1372 367369
Related Links
Latest News
Service Datasheets
Related Case Studies
Report Available by Topic
 
Asta BEAB

ERA Technology is a registered supplier on the Utilities Vendor Database (UVDB)
ERA is as a registered supplier on UVDB Verify.
 
 
ERA Technology is a Cobham Company Electrical Power Testing - pdf